Error 404

Category:
Description Information Reviews
Model: RPM-9000C2 Portable Dental Oral implant?Patient Monitor is adaptable to adult, pediatric and neonatal usage.It?can be used in oral implant surgery. It can monitor and measure human body's vital signs in real time for patients, especially patients with cardiovascular and cerebrovascular diseases and diabetes, and monitor the changes of life signs in real time, and provide basis for oral implant. Features: 10 inch color high resolution TFT display. Can be arbitrarily set the alarm limit, automatic sound and light alarm Anti-movement, anti-defibrillation, anti electrosurgical interference Remote central monitoring network interface Drug solubility calculation function, Arrhythmia analysis function Built-in lithium battery, AC and DC, can provide long-term monitoring after power failure Widely used in the Department of internal medicine, Dental practices (both pediatric and adult), oral surgery centers surgery, operation room,obstetrics and Gynecology, pediatrics, emergency center, ICU, CCU.?? Standard configuration: ECG, NIBP, SPO2, TEMP, RESP,PR Specification: ECG Lead Mode:5 Leads (?R, L, F, N, C or RA, LA, LL, RL,V) Lead selection:I, II, III, avR, avL, avF, V, Waveform:2 ch Lead mode:3 Leads ( R, L, F or RA, LA, LL) Lead selection:I, II, III, Waveform:1 ch Gain:′2.5mm/mV, ′5.0mm/mV, ′10mm/mV, ′20mm/mV, auto HR and Alarm? Range:? Adult:15 ~ 300 bpm Neo/Ped:15 ~ 350 bpm Accuracy:± 1% or ± 1bpm,which great Resolution:1 bpm Sensitivity:> 200 (uV P-P) Differential Input Impedance:> 5 MΩ RESPARATION: Method:Impedance between R-F(RA-LL) Differential Input Impedance:>2.5 MΩ Measuring Impedance Range:0.3~5.0Ω Base line Impedance Range:0 – 2.5 ?KΩ Bandwidth:0.3 ~ 2.5 Hz Resp. Rate Measuring and Alarm Range? Adult:0 ~ 120 rpm Neo/Ped:0 ~ 150 rpm Resolution:1 rpm Accuracy:±2 rpm Apean Alarm:10 ~ 40 S NIBP Method:Oscillometric Mode:Manual, Auto, STAT Measuring Interval in AUTO Mode ?1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min) Measuring Period in STAT Mode:5 Min Pulse Rate Range:40 ~ 240 bpm Alarm Type:SYS, DIA, MEAN Measuring and alarm range:??? Adult Mode SYS :40 ~ 270 mmHg DIA :10 ~ 215 mmHg MEAN:20 ~ 235 mmHg Pediatric Mode SYS:40 ~ 200 mmHg DIA:10 ~ 150 mmHg MEAN:20 ~ 165 mmHg Neonatal Mode SYS:40 ~ 135 mmHg DIA:10 ~ 100 mmHg MEAN:20 ~ 110 mmHg Overpressure Protection Adult Mode:297±3 mmHg Pediatric Mode:240±3 mmHg Neonatal Mode:147±3 mmHg SpO2 Measuring Range:0 ~ 100 % Alarm Range:0 ~ 100 % Resolution:1 % Accuracy:????? 70% ~ 100% ?±2 % 0% ?~ ?69% ?unspecified Actualization interval:about 1 Sec. Alarm Delay:10 Sec. Pulse Rate Measuring and Alarm Range:0~254bpm Resolution:1bpm Accuracy:±2bpm I.5TEMP measurement: Channel:1 Measuring and Alarm Range:0 ~ 50 °C Resolution:0.1°C Accuracy:±0.1°C Actualization interval:about 1 Sec. Average Time Constant:< 10 Sec. Package List: 1×Dental Patient Monitor 1×EKG Lead wire 1×NIBP Cuff 1×NIBP Extension Cable 1×SpO2 Sensor 1×Temp Sensor 3×Limp Clip 5×Electrode 1×User ManualOriginally purchased new for medical office. Opened but never used. All in excellent working condition
Name Value
All returns acceptedReturnsNotAccepted
BrandUnbranded
TechnologyDigital
ModelPM12D
Featuresportable
MPNDoes Not Apply
Country/Region of ManufactureChina
Unit Quantity4
Monitor ParametersMonitor Parameters
Intended Use/DisciplineEmergency Medicine

Reviews

There are no reviews yet.
Be the first to review Portable 10"Medical Patient Monitor Vital Signs ICU ECG NIBP RESP TEMP SPO2 PR A
Your email address will not be published. Required fields are marked *
Your rating

Recommended Products

Expert Customer Service

Contact Us We're open for business 24/7 !
TRUSTED STORE
CERTIFIED SECURE
Scroll To Top
Close
Close
Close

My Cart

Shopping cart is empty!

Continue Shopping